Insights

4 Tips to be looking out for in an Emergency Conversion Kits

The occurrence of power failure is not an oddity, but when it does happen in public buildings such as a theater, Hotel, retail stores, or restaurants, evacuation can most certainly become a challenge, destructive even. But with the guidance of emergency lighting, such circumstances are on most occasions well contained. And that happens to be why this indispensable equipment is gaining global recognition at this point. In some countries, it’s even mandatory for buildings to install emergency lighting.

Most companies, however, happen to have made the grave mistake of giving more notice to price than quality. And purchasing emergency lightings that are of inferior quality is basically a nightmare. Low quality emergency lightings are prone to system failure. If, for instance, the battery and the charger are of poor quality, the emergency power pack would be unable to provide sufficient illumination for the escape routes, and the lamps might collapse.

And system failure in emergency lightings might lead to incredibly devastating casualties, such as death, personal injury, property damage and so forth.

So if you’re going to invest in these incredibly valuable equipments, then it would be best for you to feast your eyes on quality rather than price. You’d better to be careful for below issues:

1.Local regulations

  • How long is the emergency duration?

Local authorities and Fire Prevention Departments quite often publish their own recommendations regarding the types of system and emergency duration, and these of course must be taken into account when designing a system as they may compliment BS 5266 or even over-ride it. It should always be borne in mind that the system, once installed will have to comply with the most stringent of the requirements, whether the British Standard or the Local Authority regulations prevail.

  • How much light?

Having decided on your basic system consideration should now be given to the siting of the lighting units and signs within the particular premises involved, which will then form the basis on which your selection of equipment can be made. The actual degree of illumination should be closely related to the nature of both the premises and its occupants with special consideration being given to old persons homes, hospitals, crowded areas such as pubs, discos and supermarkets, and to whether or not the premises are residential. Such as BS5266 recommends a minimum level of only 0.2 in corridors (permanently unobstructed) and 0.5 lux minimum for anti- panic areas to exclude 0.5 meter border around the room. (Detailed computer point calculations or luminaire manufacturers spacing tables should be used).

2.Batteries

  • Choose ideal battery to fit with your lighting fixture and requirements

As a result of high temperatures and frequent charging, Inevitably the performance of any battery is gradually degraded during its life. The conditions of temperature and continuous overcharge prevailing in emergency lighting are particularly harsh and accelerate the degradation.So it’s best to opt for first-class batteries that have high-temperature cells, NiCd for optimal efficiency and safety, NiMH for optimal energy density and environment friendly, Li-ion for low cost and extremely small dimensions, and have a range of configurations for any application.

The battery must be compliance with ICEL1010 license and application of ICEL label.Current standards for emergency lighting, both product standards and application standards, require a battery life of four years and up to that life the emergency lighting must be capable of providing emergency light for its full rated duration.The producers will be entitled to apply the ICELto the battery and/or literature.

  • Testing

All test data shall be presented to ICEL within formal reports. The cell shall undergo a Charge Acceptance Test,Permanent Charge Endurance Test.The
actual discharge duration shall be recorded and reported and the minimum discharge duration shall be no less than 3 hours at a final voltage of 1.00V. The longest discharge time from cycles 2 and 3 shall be used to calculate the battery capacity. Be careful some of supplier sell lower capacity battery at best quality(bigger capacity) price.

3.Control system-Convertor

The other element in emergency lighting that has to be of superior quality is the control system. The design of this control system has to be simple and easy to operate.

The Control System is ideal for integrating into existing control gear. It is equipped with driver, inverter and high temperature battery pack. Supplied with a fused terminal block and pre-cut connection wires, the modules can be tuned specifically to the lamp.

With a constant feed the batteries charge in 24 hours. So, if the main power is disrupted, the batteries kick in with light flicking in just 0.1 second.

The Emergency Light Kit can be configured with different back-up period and different light output levels.

The control systems can even generate test logs.Evaluating the quality of the various components of the emergency lightings conversion kits you purchase might be a tough challenge, so one way to approach this matter is by consulting  quality control professionals.

4.Certification

Another way of determining the quality of emergency light kits is by making sure they have passed the international standards and are certified. Such are the certifications you should be looking for; BS for British Standards, BS ES for British and European Standard, CE for Europe, UL for the U.S., and test AS2293 for Australia.

Jenny

Jenny Tan has over 9 years of experience in marketing LED emergency power supply products to the global market with in-depth technical expertise on emergency conversion kits, drivers, rechargeable batteries and lightings of various makes.

Recent Posts

Emergency Lighting Solutions for Australian Mining Operations: Addressing Remote Site Challenges

Australia’s mining industry operates in some of the most challenging environments, with remote sites often…

1 week ago

Enhancing Emergency Preparedness in South African Power Plants: Implementing Constant Power Emergency Drivers

Emergency preparedness is a cornerstone of operational safety and reliability in power plants. In South…

1 week ago

Safety Standards in Brazilian Automotive Assembly Plants: The Role of Energy-Saving Emergency Drivers

Brazil's automotive industry is one of the largest and most influential in the world, ranking…

1 week ago

Optimizing Emergency Lighting in British Data Centers: Protecting Critical Infrastructure

Data centers are the backbone of modern digital infrastructure, supporting critical industries such as finance,…

1 week ago

Protecting Critical Infrastructures With Emergency Drivers: The Hydropower Case

Hydropower plants play a vital role in Nepal's energy production, supplying a significant portion of…

2 weeks ago

How Emergency Lightings Can Assist Cement Factories in Bhutan & Elsewhere?

In Bhutan, cement factories face strict regulations that are designed to safeguard both workers and…

2 weeks ago